What size hot water system do I need?
- Written by
- One Stop Plumbing & Hot Water
- NSW Lic.
- 500011C
- Sources checked
- 5.0 · 6 reviews
Start at about 50 litres of hot water per person a day, then size for how it heats: off-peak electric, gas, heat pump or continuous flow.
Quick answer20 sources
What size hot water system does a family of four need?
As a guide from CHOICE: an electric tank of 125–160 litres on a continuous tariff or 250–315 litres on off-peak, a gas storage tank of 135–170 litres, a heat pump of 270–315 litres, or a solar tank of 300–360 litres. For gas continuous flow, Rheem rates a 20 L/min unit for a four-person household. Long or overlapping showers and your tariff move you up or down a size.
Start with how much hot water you use
YourHome, the Australian Government's home energy guide, puts typical use at about 50 litres of hot water per person per day, and says to check your own household before choosing. Four people is roughly 200 litres a day. Then adjust for how you use it.
- Showers and baths use most of it (YourHome). Sydney Water says a standard showerhead uses around 9 litres a minute, older heads 15–25 litres and an efficient one 6–7 litres. Rheem and Dux both say shower use is what households underestimate.
- Timing matters too. CHOICE's sizing questions ask when you shower as well as how many of you there are: four showers back to back at 6.30 am ask more of a system than the same four spread across the day.
- Appliances may not count. Many front loaders and most dishwashers take cold water only and heat their own (CHOICE).
- Plan for the next few years. If the kids are young, size for the teenagers they'll become.
Typical sizes for a household of four
| System | Typical size for 4 people | Why that size |
|---|---|---|
| Electric storage, continuous tariff | 125–160 L | The element switches back on whenever the water cools, so the tank only has to cover a busy stretch. |
| Electric storage, off-peak | 250–315 L | It heats overnight only, so it has to hold the whole day's hot water. |
| Gas storage | 135–170 L | Gas reheats quickly, so a smaller tank keeps up (YourHome). |
| Heat pump | 270–315 L | Heats from the air, which can take longer; most include a booster element for cold days and heavy use (CHOICE). |
| Solar | 300–360 L, plus about 4 m² of collectors | Stores the day's sun; a gas or electric booster covers the shortfall. |
| Gas continuous flow | 20 L/min | Sized by flow, not storage (Rheem). |
Note Tank sizes from CHOICE's hot water buying guide (last updated 5 April 2024); continuous flow from Rheem's sizing guide (17 January 2024). Guides, not rules: check the sizing table for the model you're buying. Checked 18 Nov 2026.
Off-peak in Western Sydney: why the tank gets bigger
Endeavour Energy runs the electricity network across Greater Western Sydney. On its Controlled Load 1 tariff, supply may not be available between 7 am and 10 pm; the tank heats in set periods overnight. Everything you use from breakfast to bedtime has to be in the tank already.
That's why YourHome says electric tanks larger than 250 litres suit controlled load, and that a smaller one can run out before the circuit switches on to recharge it. Energy Rating says it more plainly: larger tanks are often used on restricted tariffs so you don't run out.
Controlled Load 2 is the middle ground: power for up to 17 hours in any 24 (Endeavour). A heat pump can go on it if its tank is at least 250 litres, and Rheem recommends its heat pumps run on a continuous tariff or an extended off-peak of at least 16 hours a day. Only homes with a separate meter for the load can have a controlled load tariff (Energy NSW); your power bill shows which tariff you're on.
Gas storage: recovery counts as much as litres
Gas heats water faster than an element, which is why gas tanks are smaller than electric ones for the same household (YourHome). The figure to compare is recovery: how much water the heater can bring back up to temperature in an hour after it runs out. Rheem's example is a 130-litre tank with 145 litres an hour of recovery through a 45 °C rise, which it quotes as 275 litres of first-hour capacity.
Stored temperature matters too. Tanks must be heated to 60 °C or more at least once a week to control Legionella (YourHome), and in NSW bathroom outlets get no more than 50 °C through a temperature control device. Dux points out that hotter stored water goes further once it's mixed with cold, and that a thermostat turned down low makes a tank run out sooner.
Continuous flow: litres per minute, not litres in a tank
A continuous-flow heater doesn't run out, but it can only heat so much water at once. Rheem's guide for its own units:
- 12 L/min: one bathroom, up to two people
- 16 L/min: one and a half bathrooms, up to three people
- 20 L/min: a four-person household
- 26 L/min: two to two and a half bathrooms, up to five people
Count the outlets you run together, not just the people. Two old 15–25 L/min showerheads running at once ask far more of a unit than two efficient 6–7 L/min heads. Energy Rating also notes continuous-flow units deliver hot water at lower pressure than storage systems, which can be a problem in heavy-use homes.
Two practical limits. Rheem notes most gas storage heaters can run off the gas pipe already in many houses, but a continuous-flow heater needs a larger-diameter pipe from the meter. And whole-house electric continuous flow draws up to 28 kW, which needs three-phase power that not every home has (YourHome).
Heat pumps: size for the cold mornings
A heat pump leans on its tank: CHOICE's range for four is 270–315 litres. Rheem says its own heat pumps may take a bit longer to heat than an electric tank, and carry an electric boost for heavy use and very cold weather.
Cold matters in this part of Sydney. Penrith Lakes has a July average minimum of 5.5 °C and Richmond 3.8 °C, with Richmond at or below 0 °C on about 13 days a year (Bureau of Meteorology). energy.gov.au warns that not all heat pumps are designed for places that regularly drop below 5 °C. In the Hawkesbury especially, choose a model rated for the cold and expect the booster element to work harder in very cold weather, as Rinnai's manual notes it may.
Two size limits to know: Endeavour's Controlled Load 2 needs a heat pump tank of at least 250 litres, and federal small-scale technology certificates apply to eligible air-source heat pumps under 425 litres (Clean Energy Regulator). Incentives are covered in our NSW hot water rebates guide, and how the types compare in heat pump vs gas vs electric.
Too big costs money too
Bigger isn't automatically safer. YourHome says a larger tank uses more energy keeping water hot, and about 30% of the energy a storage system uses is lost as heat from the tank and pipework, more in homes that use little hot water. Rheem puts it simply: too large and you pay to heat and store water you don't use.
Too small costs more than cold showers. Rheem's electric heavy-duty warranty says that if a heater isn't sized to the household's demand under its guidelines, any resulting fault isn't covered.
What else limits the size you can fit
- Space and access. YourHome notes larger tanks need more room for maintenance access, and indoor tanks need a drip tray drained to a suitable waste point.
- Gas goes outside. The NSW Government says new and replacement gas water heaters should be installed outside the building.
- Heat pump airflow and noise. It needs clear air around it (Rinnai's example wants 500 mm on the fan side), and it mustn't be heard in a neighbour's living areas or bedrooms before 7 am on weekdays (8 am weekends and public holidays) or after 10 pm (NSW EPA).
Signs your current system is the wrong size
- An off-peak tank that's empty by evening most days.
- The second or third shower in a row goes lukewarm.
- A continuous-flow unit that can't keep two showers hot at once.
- The thermostat has been turned up to keep up. Rheem warns hotter water increases the scald risk.
Rule out faults before upsizing: a relief valve running, a leaking hot water pipe or a thermostat set low can all look like a tank that's too small. Our no hot water guide goes through the checks. When you're ready to choose, tell us how many people, bathrooms and showers you have and which tariff you're on, and your hot water replacement quote will be sized to suit.
Tell us your household and we'll size the system and fix the price before any work starts.
03Get it fixed
Get it fixed by a licensed plumber.
Plumbing, drainage and gasfitting are licensed work in NSW, whatever the job costs. These are the services that fix what this guide describes.
Hot Water Systems
Gas, electric, heat pump and solar: repaired when it's worth it, replaced when it isn't.
Heat Pump Hot Water Installation
Sized for cold mornings, placed for the neighbours, with NSW discounts explained.
Electric Hot Water Repairs & Replacement
Not heating, tripping or running out early: found, fixed or replaced to NSW rules.
Gas Hot Water Repairs & Replacement
Storage or continuous flow, natural gas or LPG: repaired, replaced and certified.
Or skip the reading
Describe it on the phone. You get a free estimate, then a fixed price before any work starts.
A plumber answers0400 949 422 Text a photoText 0400 949 4225.0 on Google · 6 reviews · November 202604General notes
Questions people ask.
Answered the way we'd answer them on the phone.
How many litres of hot water does one person use a day?
About 50 litres, according to YourHome and CHOICE. Long showers and hot-water washing push it up; efficient 6–7 L/min showerheads bring it down.
Is a 250 litre hot water system big enough for four people?
It depends on the type and tariff. For off-peak electric, 250 litres is the bottom of CHOICE's 250–315 litre range for four. On a continuous tariff it's more than CHOICE's 125–160 litres. For a heat pump it sits just under CHOICE's 270–315 litres, and 250 litres is the minimum Endeavour allows for a heat pump on Controlled Load 2.
What size hot water system do I need for a family of five?
Start from about 250 litres of hot water a day (five people at YourHome's 50 litres each) and size for your peak. For gas continuous flow, Rheem rates a 26 L/min unit for up to five people with two to two and a half bathrooms. An off-peak electric tank has to hold the whole day's use, so scale up from the 250–315 litres CHOICE gives for four.
What size hot water system do I need for a 4 bedroom house?
Size by people, bathrooms and showers, not bedrooms. A four-bedroom house with two adults uses far less than one with five teenagers. Count the people, the showers that run at the same time and your tariff, then use the per-person and per-type figures on this page.
How long does a 315 litre hot water system take to heat?
An electric 315-litre tank with a single 4.8 kW element needs a bit under four hours to heat from cold (about 82 litres an hour through a 50 °C rise, our calculation, ignoring heat losses). On Controlled Load 1 that only happens in the overnight window. A heat pump may take longer (Rheem), and gas storage recovers faster.
Does a bigger hot water tank cost more to run?
Yes, all else being equal. YourHome says a larger tank uses more energy keeping the water hot, and heat lost from a storage tank and its pipes can be up to a third of the system's energy use. Pick the size that covers your peak, not the biggest that fits.
05Related guides
Read next.
Buyer's guideHot water
Heat pump, gas or electric hot water: which suits a Western Sydney home?
Replacing an electric tank? A heat pump is usually cheapest to run and gets incentives, but costs more up front than gas or electric.
Buyer's guideHot water
NSW hot water rebates in 2026: heat pump and solar discounts explained
In NSW, help with a new hot water system is mostly a discount on the installer's quote, and only for eligible heat pumps and solar.
Buyer's guideHot water
Repair or replace your hot water system? How to decide
Repair it when a replaceable part has failed and the tank is sound; replace it when the tank itself leaks. Age and warranty settle the rest.
06References
20 sources.
The pages this guide relies on, linked, with the date each one was read: all checked between 18 November 2026 and 19 November 2026.
- YourHome — Hot water systemsChecked
- CHOICE — Hot water systems buying guide (last updated 5 April 2024)Checked
- Rheem — How do I know which size water heater is right for me? (17 January 2024)Checked
- Rheem — FAQs (heat pump tariffs, gas pipe size for continuous flow)Checked
- Rheem — Owner's guide and warranty, electric heavy-duty water heaters (122048 Rev 01, July 2023; PDF, 1.9 MB)Checked
- Dux — Technical information (thermostat settings and tempering)Checked
- Dux — Prodigy 4 and 5 gas storage owner's manual (H3109 Rev L; PDF, 1.1 MB)Checked
- Rinnai — Enviroflo AR heat pump operation and installation manual (PDF)Checked
- Endeavour Energy — Network Price List 2026-27, controlled load (section 8; PDF, 692 KB)Checked
- Endeavour Energy — Who we are (network area: Greater Western Sydney and the Blue Mountains)Checked
- Energy NSW — Electricity tariffs (controlled load needs a separate meter)Checked
- Energy Rating — Water heatingChecked
- Sydney Water — Water saving tips for the home (showerhead flow rates)Checked
- energy.gov.au — Hot water systemsChecked
- Bureau of Meteorology — Climate statistics, Penrith Lakes AWSChecked
- Bureau of Meteorology — Climate statistics, Richmond RAAFChecked
- Clean Energy Regulator — Solar water heaters and air source heat pumps (STCs)Checked
- Building Commission NSW — Advisory Note 3/2026, temperature requirements for heated waterChecked
- NSW Government — Gas water heatersChecked
- NSW EPA — Preventing neighbourhood noise (heat pump hours)Checked