Open now · 24 hours, 7 days
Problem · Hot water
01ProblemHot water
No hot water? What to check first
- Written by
- One Stop Plumbing & Hot Water
- NSW Lic.
- 500011C
- Sources checked
- 5.0 · 6 reviews
Check whether every hot tap is cold, then the power, off-peak hours, gas, pilot or error code. Still no heat? A part has probably failed.
Quick answer24 sources
Why have I suddenly got no hot water?
Either the heater has lost what it runs on, a safety device has shut it down, or a part has failed. Electric and heat pump units need power, and off-peak tanks only heat at set hours. Gas storage units need gas and a lit pilot. Continuous-flow units need gas, power and enough flow, and usually show an error code when they stop. If all of that checks out, call a licensed plumber.
02Do this now
Safe first steps, in order.
Smell gas? Don't try to light the heater. Put out naked flames, don't smoke or use your phone near the smell, and leave the building. From outside, call 000 and ask for Fire and Rescue NSW, and report it to Jemena on 131 909 (on bottled gas, your gas supplier).
Water pouring from the heater or its relief valve pipe? Stand clear of the relief valve drain: what comes out can be scalding. Turn the heater off (the hot water switch at the switchboard, or the gas control knob to off and the gas valve on its pipe closed), then close the cold water valve into the heater.
Run a hot tap in the kitchen and one in the bathroom. Hot at the sink but not in the shower usually means the heater is working.
Electric or heat pump: check the hot water switch at the switchboard (often labelled 'Hot water') and any isolating switch beside the heater are on, and that the circuit breaker hasn't tripped. If it trips again after you switch it back on, leave it off and call an electrician.
Off-peak tank empty by evening? It may just be used up. It reheats overnight.
Gas storage: check another gas appliance lights and the gas valve to the heater is open (on LPG, check the bottles). Relight a pilot only if there's no gas smell, and only by the instructions inside the access cover.
Continuous flow: write down the error code. Close the hot tap, switch the unit off and on at its power point, then open the tap again. If the code returns, call.
Done the checks and it's still not right? Call and say what it's doing.
Written by One Stop Plumbing & Hot Water · NSW Lic. 500011C · sources checked
Quick answer24 sources
Why have I suddenly got no hot water?
Either the heater has lost what it runs on, a safety device has shut it down, or a part has failed. Electric and heat pump units need power, and off-peak tanks only heat at set hours. Gas storage units need gas and a lit pilot. Continuous-flow units need gas, power and enough flow, and usually show an error code when they stop. If all of that checks out, call a licensed plumber.
First: every tap, or just some?
Run the hot tap at the kitchen sink and at a bathroom basin for a minute each. What you find tells you where to look.
- Cold everywhere. The heater isn't heating, or it has run out. Work through the checks for your type of system below.
- Hot in the kitchen, lukewarm in the bathrooms. The heater is probably fine. NSW rules cap the water at bathroom fixtures (showers, baths, basins, bidets) at 50 °C, so the bathrooms may be fed through a tempering valve while the kitchen runs straight off the heater (Dux describes this as one installation option). Dux says a tempering valve isn't serviceable and should be replaced every five years. A valve job, not a new heater.
- No water at all, hot or cold. That's the supply, not the heater. Check the meter tap (usually at the front of the property) is fully on, and ring Sydney Water's faults line on 13 20 90 (24/7) about outages.
- Hot water that runs out or fades mid-shower. The heater works but isn't keeping up. Usage, tariff and tank size are the places to look.
Electric storage: power first, then the tariff
Rheem's owner's guide lists the checks before calling anyone: is the isolating switch on, has the fuse or circuit breaker tripped, and is the heater on a time-controlled supply where heating hours are restricted.
If the circuit keeps tripping, leave it off. A safety switch cuts the power when it detects current leaking from a circuit, the NSW Government explains, so a heater that keeps tripping it points to an electrical fault. Wiring work is for a licensed electrician.
Off-peak tanks run dry in the evening. Endeavour Energy runs the electricity network across Greater Western Sydney, and on its Controlled Load 1 tariff, supply may not be available between 7 am and 10 pm. The tank heats overnight, so use it up by early evening and there's no more until the next night. That's a size or usage problem, not a fault; our guide to what size hot water system you need explains why off-peak tanks have to be bigger.
What not to touch. The thermostat, element and over-temperature cut-out sit behind a cover hiding 240-volt wiring. Rheem says only a qualified person may take that cover off, thermostat adjustments are for a licensed electrical worker, and an over-temperature cut-out that has operated must not be reset. Rheem calls a tripped cut-out a possibly dangerous situation: something got too hot, and the reason needs finding.
Gas storage: the supply, then the pilot
Most gas storage heaters keep a small pilot flame burning to light the main burner. Check the supply first: is the gas valve on the pipe into the heater open, and does another gas appliance, like the cooktop, light? If nothing in the house has gas, Rheem's advice is to call your gas supplier. On LPG, check the bottles.
Rheem and Dux both put the pilot lighting instructions inside the access cover, and both start with turning the control off and waiting five minutes so any unburnt gas can clear. Rheem wants the steps followed exactly, and adds: check there's no smell of gas near the heater first, down at ground level too, because gas can settle there, and turn the knob by hand, never with a tool.
If the pilot won't light, or lights and goes out again, stop there. Gas appliance repairs are licensed gasfitting work in NSW, and the NSW Government recommends a gas water heater be serviced by a licensed gasfitter once a year anyway.
Continuous flow: gas, power and enough flow
A continuous-flow unit heats water only as it flows through, so it needs gas, electricity and enough flow. Lose the power and you can lose the hot water: CHOICE notes gas heaters with electric ignition can stop in a blackout.
When one stops, it usually shows an error code. For Rheem's code 11 (ignition failure), Rheem says to check the bottle level if you're on LPG, close the hot tap, switch the power off and on at the power point, then open the tap again. If the code comes back, it needs a service. Write the code down before you call; it narrows the fault a long way.
Water that surges hot and cold is a different problem: Rheem says the flow may be too low to keep the unit running, which flow restrictors and low-flow taps can cause, and it needs at least two to three litres a minute. On Rinnai Infinity units, an LC code means scale build-up in the heat exchanger, which needs a service call.
Heat pumps and solar: slower, with a booster
A heat pump takes its heat from the outside air, and Rheem says its own may take a bit longer to heat than an electric tank. Check the isolating switch as for an electric tank. Rinnai's manual for one model notes a delay before the compressor starts, and says the compressor may stop below −7 °C or above 45 °C, with the electric element taking over.
Winter mornings test them here. The July average minimum is 5.5 °C at Penrith Lakes and 3.8 °C at Richmond (Bureau of Meteorology), and energy.gov.au warns that not all models are designed for places that regularly drop below 5 °C. Ice on the coil isn't a fault by itself; Rinnai's model has a defrost cycle. A heat pump that runs short every cold morning may be the wrong model or size, not broken.
Solar systems lean on a gas or electric booster when the sun can't keep up. If yours goes cold in winter or after grey days, check the booster is on and its timer set, using the owner's guide. If that's fine, have the booster and collectors checked.
Back from holidays and it's cold?
YourHome, the Australian Government's home energy guide, says you can switch the system off at the meter board while you're away, so check it's back on. Then run it for several hours so the stored water gets above 60 °C for at least 35 minutes, which kills Legionella bacteria.
If the heater sat unused for two weeks or more, Dux warns that hydrogen, which is highly flammable, can collect in the tank. Its advice: run a hot tap at a sink, basin or bath (not a dishwasher or washing machine) for several minutes, with no smoking, flames or electrical appliances running nearby.
When it's a job for a plumber
Call a licensed plumber when the supply checks out and it still won't heat, a pilot won't stay lit, a continuous-flow code keeps coming back, the bathrooms are lukewarm and the kitchen isn't, or water is running from the relief valve (see our leaking hot water system guide). In NSW, plumbing and gasfitting work needs a licence whatever the job costs.
A cold shower on its own can usually wait for business hours. A gas smell or water pouring from the heater can't. Our guide to what counts as a plumbing emergency goes through where the line sits.
Before you ring, photograph the label on the side of the heater (brand, model, manufacture date) and note any error code. Call 0400 949 422 and tell us what it's doing: you'll get a free phone estimate, and a fixed price agreed before any work starts. If the heater is near the end of its life, see repair or replace and our hot water repairs and replacement page.
Still cold after the checks? Call and tell us what it's doing.
A plumber answers0400 949 42204Get it fixed
Get it fixed by a licensed plumber.
Plumbing, drainage and gasfitting are licensed work in NSW, whatever the job costs. These are the services that fix what this guide describes.
Hot Water Systems
Gas, electric, heat pump and solar: repaired when it's worth it, replaced when it isn't.
Gas Hot Water Repairs & Replacement
Storage or continuous flow, natural gas or LPG: repaired, replaced and certified.
Electric Hot Water Repairs & Replacement
Not heating, tripping or running out early: found, fixed or replaced to NSW rules.
Heat Pump Hot Water Installation
Sized for cold mornings, placed for the neighbours, with NSW discounts explained.
Or skip the reading
Describe it on the phone. You get a free estimate, then a fixed price before any work starts.
A plumber answers0400 949 422 Text a photoText 0400 949 4225.0 on Google · 6 reviews · November 202605General notes
Questions people ask.
Answered the way we'd answer them on the phone.
How do I reset my hot water system?
You can reset the power, a continuous-flow unit and a gas pilot yourself, but never the over-temperature cut-out inside an electric heater. Switch a tripped hot water circuit back on once at the switchboard, switch a continuous-flow unit off and on at its power point (Rheem's advice for an ignition fault), and relight a pilot only if there's no gas smell, following the instructions inside the access cover. Rheem says a cut-out that has operated must not be reset; the heater needs a qualified person.
Do I call a plumber or an electrician for no hot water?
It depends where the fault is. Water, valves, gas and the heater itself are plumbing and gasfitting work, which needs a licensed plumber or gasfitter in NSW. The element, thermostat and wiring inside an electric heater are electrical work, and the NSW Government says wiring work is for a licensed electrician. If the circuit keeps tripping, start with an electrician. If you can't tell, ring us and we'll say which trade you need.
Why is my hot water only lukewarm?
Either the water isn't getting hot enough or too much cold is being mixed in. If only the bathrooms are lukewarm, suspect the tempering valve. If every tap is lukewarm, the tank may still be reheating, the thermostat may be set low (Dux notes a low setting also makes the tank run out sooner), or a continuous-flow unit may be getting too little flow to stay lit.
Why does my hot water run out so fast?
Often because more hot water is being used than the heater can store or reheat; Rheem and Dux both say shower use is what people underestimate. Other causes are off-peak heating hours, a relief valve letting out too much water, a leaking hot water pipe or dripping hot tap, or a heater that was too small to begin with.
Why won't my hot water pilot light stay on?
If it won't stay lit after you've followed the lighting instructions exactly, stop relighting it and book a licensed gasfitter. The pilot, thermocouple, spark gap and gas control valve are all on Dux's annual service list, and Dux says the gas control valve may only be replaced by a licensed tradesperson or the manufacturer.
Why is my hot water not working after a power outage?
Because some systems need power to heat or to restart. A gas continuous-flow unit needs electricity as well as gas, and CHOICE notes you can lose hot water in a blackout. If it shows an ignition code once the power is back, Rheem's fix is to close the hot tap, switch the unit off and on at the power point and open the tap again. For electric and heat pump units, check the hot water switch at the switchboard is on, and remember an off-peak tank that lost power overnight may not have finished heating.
06Related guides
Read next.
ProblemHot water
Hot water system leaking? What it means and what to do
Find where the water comes from first: a little from the relief drain is normal, a dripping joint is a fitting, a weeping tank has failed.
Buyer's guideHot water
Repair or replace your hot water system? How to decide
Repair it when a replaceable part has failed and the tank is sound; replace it when the tank itself leaks. Age and warranty settle the rest.
Buyer's guideHot water
What size hot water system do I need?
Start at about 50 litres of hot water per person a day, then size for how it heats: off-peak electric, gas, heat pump or continuous flow.
07References
24 sources.
The pages this guide relies on, linked, with the date each one was read: all checked between 18 November 2026 and 19 November 2026.
- Rheem — Owner's guide, electric heavy-duty water heaters (122048 Rev 01, July 2023; PDF, 1.9 MB)Checked
- Rheem — Owner's guide, gas outdoor water heaters 850 and 854 series (122635 Rev D; PDF, 1.4 MB)Checked
- Rheem — Troubleshooting guide (continuous flow error codes and minimum flow)Checked
- Rheem — FAQs (heat pump heating time and boost)Checked
- Dux — Prodigy 4 and 5 gas storage owner's manual (H3109 Rev L; PDF, 1.1 MB)Checked
- Dux — Technical information (tempering valves, thermostat settings)Checked
- Rinnai — Enviroflo AR heat pump operation and installation manual (PDF)Checked
- Rinnai — Infinity gas continuous flow operation and installation manual (LC code; PDF)Checked
- Endeavour Energy — Network Price List 2026-27, controlled load (section 8; PDF, 692 KB)Checked
- Endeavour Energy — Who we are (network area: Greater Western Sydney and the Blue Mountains)Checked
- NSW Government — Electrical safety in the homeChecked
- NSW Government — Gas water heatersChecked
- NSW Government — Gas safety requirements and consumer rightsChecked
- Jemena — Gas safety (faults and emergencies 131 909)Checked
- Building Commission NSW — Advisory Note 3/2026, temperature requirements for heated waterChecked
- NSW Government — Plumbing, draining and gasfitting licencesChecked
- YourHome — Hot water systemsChecked
- energy.gov.au — Hot water systemsChecked
- CHOICE — Hot water systems buying guide (last updated 5 April 2024)Checked
- Bureau of Meteorology — Climate statistics, Penrith Lakes AWSChecked
- Bureau of Meteorology — Climate statistics, Richmond RAAFChecked
- Sydney Water — Contact us (faults line 13 20 90)Checked
- Sydney Water — Leak detection (where the meter is)Checked
- Rheem — How do I know which size water heater is right for me? (continuous flow needs gas and power; 17 January 2024)Checked
